K-Type Thermocouple 17 point (16 interval) conversion table. Raw error is less than 0.5°C over 0°C to 1220°C. Assume 10 bit ADC, Gain = 101, 5 Volt = 1023 count, linear interpolation. ADC K-Type Integer Error Error 1-Step Count Temp Approx 1-step 16-step Approx 0 0 0 0 0 0 64 75.915 76 -0.232 0.085 76.23 128 151.397 151 -1.464 -0.397 152.46 192 228.716 229 0.304 0.284 228.7 256 304.321 304 -0.928 -0.321 304.93 320 378.371 378 -3.16 -0.371 381.16 384 451.565 452 -5.392 0.435 457.39 448 524.276 524 -9.624 -0.276 533.62 512 596.98 597 -12.85 0.02 609.86 576 670.113 670 -16.09 -0.113 686.09 640 744.165 744 -18.32 -0.165 762.32 704 819.385 819 -19.55 -0.385 838.55 768 895.985 896 -18.79 0.015 914.78 832 974.099 974 -17.02 -0.099 991.02 896 1053.86 1054 -13.25 0.141 1,067.25 960 1135.54 1136 -7.481 0.458 1,143.48 1024 1219.68 1220 0.287 0.321 1,219.71